Extraction Well No. 1

2 Documents in Project

Summary

SCH Number
2014122069
Lead Agency
Stockton East Water District
Document Title
Extraction Well No. 1
Document Type
NOD - Notice of Determination
Received
Posted
1/27/2015
Present Land Use
Water Treatment Plant Facility / P-F / P
Document Description
Construction of a new groundwater well on the premises of the Dr. Joe Waidhafer Drinking Water Treatment Plant (DJWDWTP). The construction involves drilling a well approximately 400 feet deep, with an estimated production rate of 2,000 GPM. The project also includes constructing a 10x18 foot concrete slab foundation and block house to protect the wellhead, motor, instrumentation, control, and electrical equipment. The well will serve as a dry year supplemental supply of raw water to the DJWDWTP. The discharge of this well will be into the South Raw Water Reservoir and all water pumped will be treated prior to delivery to the Urban Contractors distribution systems.

Contact Information

Name
Scot A. Moody
Agency Name
Stockton East Water District
Contact Types
Lead/Public Agency

Location

Cities
Stockton
Counties
San Joaquin
Cross Streets
East Main Street
Zip
95215
Total Acres
.045
Parcel #
101-170-35
State Highways
Hwy 26 & 99
Railways
Santa Fe
Airports
No
Schools
Fkln, Vanderbilt, Elmwd
Waterways
Stockton Diverting Canal, Mosher Slough, Calaveras Rv
Township
1N
Range
7E
Section
76

Notice of Determination

Approving Agency
Stockton East Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
No
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.